CDF-230P Fuel Monitor Cartridges
CDF-230P Fuel Monitor Cartridges Image
Available Stock
Parker Velcon CDF Fuel Monitor Cartridge, qualified to EI 1583 6th Edition, 7/8 in ID x 1-3/4 in OD x 30-13/16 in len, 0.5 micron, Buna-N, outside-to-in at flow 30 gpm, change at 25 psid.
    • Brand: Parker Velcon
    • I.D.: 7/8 in
    • Length: 30-13/16 in.
    • Micron Rating: 0.5
    • O.D.: 1-3/4 in
    • Product Family: CDF Series
    • Product Type: Cartridge

The Velcon CDF P cartridges are designed to provide superior performance and reliability in standard fuel monitor housings through a unique, proprietary combination of media that absorbs water, filters solids that may be present in the fuel and reduces static charge.

The cartridge has injection molded endcaps that are bonded to the media and an O-ring seal on the outlet end. This minimizes the possibility of bypassing contaminated fuel or transmission of water downstream at low flow rates.

As the cartridge removes water and/or dirt from the influent fuel, differential pressure will increase and the flow rate will decrease. These changes are the result of flow restriction caused by dirt retention or water absorption in the media. The rate of these changes depends on the quantity of water or dirt contamination in the fuel.

Benefits
CDF P are qualified to EI 1583 Sixth Edition specification for Aviation Fuel Filter Monitors.
Improved: salt water performance, water capacity, water removal efficiency
Conductive end caps, O-rings, and adhesive reduce static charge within the vessel.
O-ring seal minimizes the possibility of bypassing contaminated fuel at differential pressures up to 175 psi.
Rugged construction collapse strength exceeds 175 psi differential pressure.
Aluminum center tube provides enhanced structural integrity and additional conductivity as further static charge protection

DFO-644PLF2TB Velcon Filter Cartridges
DFO-644PLF2TB Velcon Filter Cartridges Image

Available Stock
Diesel fuel is stored and transferred multiple times from refining to dispensing. Preventative action does not always eliminate contamination. Common contaminants introduced during transportation include both extremely fine and abrasive silica as well as pipe scale. These contaminants can quickly deteriorate fuel quality below engine manufacturer standards, reducing the durability and performance of the engine.

Velcon’s DFO filters transform contaminated fuels to meet stringent downstream ISO 4406 cleanliness standards for the demanding limits placed on diesel and biodiesel fuels. The DFO design balances high surface area and depth filtration to maximize filter life which reduces filtration costs.

Tiered Ratings

To meet industry fuel quality standards, Velcon developed pleated media filters for diesel and biodiesel fuels. In accordance with ISO standards, the DFO filters were designed with tiered media classification using absolute rated media. Each media tier provides a unique solution from managing fuel contamination to final fuel conditioning.

• DFO filters with ratings of 2 and 4 micron are the ultimate solution to condition fuel for dispensing while assuring ISO 4406 Cleanliness Standards are consistently met. Each progressively tighter DFO filter rating delivers additional particle removal and fuel cleanliness; therefore progressively lower ISO 4406 particle counts.

• The mid-range DFO filters of 6 and 10 micron extend filter life following secondary conditioning by removing particulate contaminants and allowing Velcon’s downstream coalescing products to focus on water removal rather than particle removal.

• The DFO filters rated at 25 and 40 micron are the ideal solution to manage contaminated fuel entering and leaving terminal storage tanks throughout the fuel transferring process.

Benefits

• Reduced operating costs by removing particulates that can cause engine damage
• Reliable fuel injector performance when particulate contaminants are removedto meet ISO 4406 Cleanliness Standards
• Improved equipment uptime, reduces equipment failures, repairs, and/or replacements

Velcon DFO Series features high efficiency particulate media and a long service life. DFO Series cartridges extend coalescer life and protect critical equipment downstream.

Features Include:

• Large Surface Area – Allows high flow rate with low initial pressure drop and maximum contaminant holding capacity.
• Resinated Media – Maintains strength resists effects of water and heat.
• 75 PSI Collapse Strength – Heavy gauge carbon steel center tubes give safety margin against pressure surges.
• Coated Steel Components – Resist corrosion from most industrial fluids.
• Corrugated Media – More surface area ensures longer service life.
• Buna-N Gaskets – The best general gasket material available assures positive seal in most fluids.
• Thermoset Bonding Material – Durable endcap-to-media bond prevents internal bypassing
• Threaded base filter cartridges – Available for easier installation.
• These are also available in screw-base design

Application:

Velcon DFO Series are designed for particulate removal from bulk diesel fuel at high flow rates. Typical applications include:

• Fuel Reception
• Bulk Fuel Storage
• Fuel Dispensing

Specifications:

• Recommended changeout differential pressure – 25 psid
• 75 psi Collapse strength
• Micron ratings from 2 to 40
• 98%+ Nominal filtration efficiency
• 5 – 9 Operating pH range
• 225°F Maximum operating temperature
• Flow rate depends on the fluid

PART NUMBER: DFO-644PLF2TB
APPLICATION: Diesel
OUTSIDE DIAMETER (INCH): 6
INSIDE DIAMETER (INCH): 3.5
LENGTH (INCH): 44
MICRON RATING (ΜM): 2
END CAP CONFIGURATION: Threaded Base
FILTER CONSTRUCTION: Pleated
SEAL MATERIAL: Buna-N

DFO-656PLF2TB Velcon Filter Cartridges
DFO-656PLF2TB Velcon Filter Cartridges Image

Available Stock

Diesel fuel is stored and transferred multiple times from refining to dispensing. Preventative action does not always eliminate contamination. Common contaminants introduced during transportation include both extremely fine and abrasive silica as well as pipe scale. These contaminants can quickly deteriorate fuel quality below engine manufacturer standards, reducing the durability and performance of the engine.

Velcon’s DFO filters transform contaminated fuels to meet stringent downstream ISO 4406 cleanliness standards for the demanding limits placed on diesel and biodiesel fuels. The DFO design balances high surface area and depth filtration to maximize filter life which reduces filtration costs.

Tiered Ratings

To meet industry fuel quality standards, Velcon developed pleated media filters for diesel and biodiesel fuels. In accordance with ISO standards, the DFO filters were designed with tiered media classification using absolute rated media. Each media tier provides a unique solution from managing fuel contamination to final fuel conditioning.

• DFO filters with ratings of 2 and 4 micron are the ultimate solution to condition fuel for dispensing while assuring ISO 4406 Cleanliness Standards are consistently met. Each progressively tighter DFO filter rating delivers additional particle removal and fuel cleanliness; therefore progressively lower ISO 4406 particle counts.

• The mid-range DFO filters of 6 and 10 micron extend filter life following secondary conditioning by removing particulate contaminants and allowing Velcon’s downstream coalescing products to focus on water removal rather than particle removal.

• The DFO filters rated at 25 and 40 micron are the ideal solution to manage contaminated fuel entering and leaving terminal storage tanks throughout the fuel transferring process.

Benefits

• Reduced operating costs by removing particulates that can cause engine damage
• Reliable fuel injector performance when particulate contaminants are removedto meet ISO 4406 Cleanliness Standards
• Improved equipment uptime, reduces equipment failures, repairs, and/or replacements

Velcon DFO Series features high efficiency particulate media and a long service life. DFO Series cartridges extend coalescer life and protect critical equipment downstream.

Features Include:

• Large Surface Area – Allows high flow rate with low initial pressure drop and maximum contaminant holding capacity.
• Resinated Media – Maintains strength resists effects of water and heat.
• 75 PSI Collapse Strength – Heavy gauge carbon steel center tubes give safety margin against pressure surges.
• Coated Steel Components – Resist corrosion from most industrial fluids.
• Corrugated Media – More surface area ensures longer service life.
• Buna-N Gaskets – The best general gasket material available assures positive seal in most fluids.
• Thermoset Bonding Material – Durable endcap-to-media bond prevents internal bypassing
• Threaded base filter cartridges – Available for easier installation.
• These are also available in screw-base design

Application:

Velcon DFO Series are designed for particulate removal from bulk diesel fuel at high flow rates. Typical applications include:

• Fuel Reception
• Bulk Fuel Storage
• Fuel Dispensing

Specifications:

• Recommended changeout differential pressure – 25 psid
• 75 psi Collapse strength
• Micron ratings from 2 to 40
• 98%+ Nominal filtration efficiency
• 5 – 9 Operating pH range
• 225°F Maximum operating temperature
• Flow rate depends on the fluid

PART NUMBER: DFO-656PLF2TB
APPLICATION: Diesel
OUTSIDE DIAMETER (INCH): 6
INSIDE DIAMETER (INCH): 3.5
LENGTH (INCH): 56
MICRON RATING (ΜM): 2
END CAP CONFIGURATION: Threaded Base
FILTER CONSTRUCTION: Pleated
SEAL MATERIAL: Buna-N

I-644MMTB Velcon Coalescer Cartridges
I-644MMTB Velcon Coalescer Cartridges Image

Available Stock

I-644MMTB Velcon Coalescer Cartridges for Aviation & Industrial

Coalescer cartridges are employed as the first stage in filter/separator vessels for hydrocarbon fluids. They perform two functions: (1) coalesce (combine) highly dispersed, emulsified water particles into larger water drops and (2) filter-out particulate contaminants.

Product Features:

– Cost effective particle and emulsified water removal from hydrocarbon fluids
– Easy installation and replacement with one-piece design
– Choice of Threaded Base or Open End cartridges
– Choice of All-Fiberglass Media or Combination Fiberglass and Pleated Media
– Field proven performance
– Ongoing qualification testing to meet changing commercial and military requirements
– Used as a first-stage cartridge in Filter/Separatos
– Remove particulates and coalesce water into large water drops
– Also available in screw base design

SO-636V5 Velcon Separator Cartridges
SO-636V5 Velcon Separator Cartridges Image

Available Stock

Features

– Optimum 2nd stage water removal
– Choice of Teflon® Coated Screen, Synthetic or Pleated Paper Media
– Field proven performance
– Largest selection of replacement elements

General

Separator Cartridges are employed as the second stage in filter/separator vessels. Their sole function is to repel coalesced water drops produced by the first stage cartridges while allowing hydrocarbon fluids to pass through. Water drops settle into the filter/separator sump and are not carried downstream. All particle filtering is done by the first stage coalescer cartridge.

PART NUMBER: SO-636V5
APPLICATION: Aviation and Industrial
OUTSIDE DIAMETER (INCH): 6
LENGTH (INCH): 36
INSIDE DIAMETER (INCH): 4.5
END CAP CONFIGURATION: Blind
MEDIA: TCS
TUBE TYPE: Variable
CERTIFICATES: EI1581
SEAL MATERIAL: Buna-N

ACO-63301P Fuel Monitor Cartriges
ACO-63301P Fuel Monitor Cartriges Image

Available Stock

Aquacon® ACO
EI 1583 6th Edition Aviation Fuel  Monitor
Remove Water and Dirt from Jet Fuel and Avgas Outside-to-In Flow Cartridges

Features

– Free and emulsified water removal to less than 5 ppm
– 1/2 micrometer particle removal
– Provides protection against “slugs” of water
– Pressure increase signals need for cartridge change
– Use with existing filter housings

Description

Patented Aquacon® Filter Cartridges have a unique high-capacity inner absorbent medium which removes all free and emulsified water from hydrocarbon fuels down to less than 5 ppm in the effluent. Absorbed water is chemically locked into this medium.

When a cartridge reaches its water holding capacity, its accordion pleats swell and cause an increase in the differential pressure which signals the operator to change the cartridge.

Solid contaminants are removed by the cartridge’s particulate filter media layers. The pleated accordion style design provides a large surface area for maximum dirt holding capacity. Models are offered for particle filtration down to 1/2 micrometer size with 98% plus efficiency.
Performance is not affected by the presence of common surface active agents.
Compact Aquacon Cartridges are quick and easy to install. Models are available to fit most existing standard housings.

Use Form VEL1846 for cartridge changeout recommendations at flowrates less than rated flow.

Technical Information

1. Max. operating temp.: 160°F (71.1°C)
2. Micron ratings are nominal at 98%+ efficiency
3. Aquacon Cartridges can significantly reduce flow when loaded with water or dirt. Appropriate precautions should be taken in applications where fuel flow must be maintained or where surge conditions can occur.
4. Replace the cartridge if the differential pressure exceeds 25 psid. For service life information, please refer to Operating Procedure #1839 or consult your company fuel handling procedures.
5. Typical water holding capacity for ACO-61401P is 700-800 ml.

NOTE:
1/2 micron rated Aquacon® Cartridges are recommended for use with jet fuel and avgas. Effluent fuel quality meets requirements for EI 1583 6th Edition.

CAUTION:
DO NOT USE WITH PRE-MIXED FUELS CONTAINING ANTI-ICING ADDITIVES (FSII)

PART NUMBER: ACO-63301P
APPLICATION: Aviation
OUTSIDE DIAMETER (INCH): 6
INSIDE DIAMETER (INCH): 3.5
LENGTH (INCH): 33.25
MICRON RATING (ΜM): 0.5
END CAP CONFIGURATION: Open-End
COLLAPSE PRESSURE (PSI): 175
MAXIMUM FLOW RATE (GPM): 133
CERTIFICATES: EI1583

I-644C5TB Coalescer Cartridges
I-644C5TB Coalescer Cartridges Image

Available Stock
Coalescer Cartridges for Aviation & Industrial

Coalescer cartridges are employed as the first stage in filter/separator vessels for hydrocarbon fluids. They perform two functions: (1) coalesce (combine) highly dispersed, emulsified water particles into larger water drops and (2) filter-out particulate contaminants.

Product Features:

– Cost effective particle and emulsified water removal from hydrocarbon fluids
– Easy installation and replacement with one-piece design
– Choice of Threaded Base or Open End cartridges
– Choice of All-Fiberglass Media or Combination Fiberglass and Pleated Media
– Field proven performance
– Ongoing qualification testing to meet changing commercial and military requirements
– Used as a first-stage cartridge in Filter/Separatos
– Remove particulates and coalesce water into large water drops
– Also available in screw base design

Application

Coalescer cartridges are used primarily to coalesce emulsified water and remove particles from hydrocarbon fluids. The largest single application is the filtration of aviation jet fuel. They are also used with other types of fuels, process streams in refineries and petrochemical plants, and condensate streams where natural gas is produced.

Other liquids can be separated if they are immiscible, the specific gravities differ, and high concentrations of surface active agents are not present. As a rule of thumb, if a sample of the mixture readily separates in an hour or two, a coalescer can probably be used. If the mixture hasn’t separated after 24 hours, coalescing probably won’t work.

Construction

Velcon single-unit coalescer elements are offered with Threaded Base or Open Ends and with Fiberglass Media or Fiberglass and Pleated Media combinations.

Threaded Base Coalescers are recommended for use in most applications. They simplify installation and replacement by eliminating the need for cover plates, center plates, nuts, washers, and gaskets. They are for use in Velcon and other make filter/ separators. Threaded base adapters are available to convert vessels presently using open end elements.

Open End Coalescers are offered with single unit construction which reduces the number of gasket seals and improves overall reliability.

All-fiberglass Media Coalescers combine depth particulate filtration with a deep coalescing structure. All-fiberglass designs have successively finer media layers to achieve depth-type filtration of particles.

Combination Fiberglass and Pleated Media Coalescers remove particles primarily in the high surface area pleated core. They have one or more layers of pleated media inside a cylinder of molded fiberglass laminations to provide an extended surface area for particulate filtration. Pleat corrugation and separation materials are used to keep pleats open for full utilization.

Coalescing and filtration performance depends largely on the fiber diameter and bulk density of the fiberglass media. Both the All-Fiberglass and the Combination coalescer cartridge designs incorporate phenolic resin impregnated fiberglass media. Several grades with fiber diameters ranging from 1 to 10 micrometers are used in various combinations to achieve desired results. Velcon’s latest coalescer designs (85, 87 and C5 series cartridges) achieve even higher filtration and coalescing efficiency by incorporating pure micro-glass fibers with diameters of less than 1 micrometer in the pleated media

Description

Model Number System. Refer to the box at right. The one or two digit Series Designator relates to the approx­imate micron rating of each model coalescer cartridge. Note that this is a nominal rating and should be used for?reference only.

The “0”, “2”, and “4” Series all-fiberglass cartridges are rated at 25, 5, and 3 microns respectively. The “2” and “4” Series are commonly used with diesel and other fuel oils, and are a compromise between filtration efficiency (cart­ridge life) and water removing capability. They coalesce gross water, but normally do not remove fine water haze.

The all-fiberglass “6” Series was originally developed for jet fuel service (the original MIL-F-8901 specification). With a 2-micron rating, it has proven to be the most cost effective design in some jet fuel applications. “6” Series cartridges are also used in gasoline filtration service. However, it should be noted that the powerful detergent additives in most automotive gasolines reduce the coalescing capability of this and other cartridge designs.
“83” Series Cartridges. The 1-micron rated “83” Series is?a pleated media/fiberglass cartridge. The very practical “83” Series cartridges have become the most widely used design in applications including gasoline, condensate, and insulating oil filtration.

“85” and “87” Series Cartridges. The “85” Series is rated at 0.5-micron while the “87” Series is rated at 0.3 micron. Both incorporate multi-layered pleated media. The “85” Series has consistently shown superior dirt holding capacity in the field.

JF5 Series Coalescers. JF5 Series Cartridges are Velcon’s newest design. Combined with V5N5 Series Separators, they offer higher flow rates and extended service life. See data sheet #1923 for more info.

EI* 1581 Fifth Edition Cartridges. I-6xxC5 (TB), I-6xxMM, and I-6xxA4 Series of coalescers incorporate a multi-layered pleated media designed to provide superior dirt holding capacity in the field, combined with 0.4 micron efficiency. The I-6xxC5 (TB) replaces both the I-6xx85 (TB) and I-6xx87 (TB) cartridges. These cartridges are available in either threaded base or open-end configuration. See data sheets 1923 and 1934 for more specific information on EI 1581 Fifth Edition.

Cartridge Dimensions. 6” diameter cartridges are the current industry standard. They are offered in lengths of?11”, 14”, 22”, 28”, 33”, 38”, 44”, and 56”. However, not?all series are available in all lengths or in both end cap designs. Contact your Velcon Distributor for details.

4” diameter cartridges are also offered for use with older equipment. They are available in a variety of lengths ranging from 8 to 40 inches.

General Specifications

– 75 psi maximum pressure differential rating
– 5 to 9 pH range
– 150°–160°F max. operating temperature
– Aluminum center tube
– Buna-N gaskets
– Injection molded end caps are standard on 6” diameter threaded base coalescers;
– Aluminum end caps are standard on 6” diameter open end cartridges
– All 6” diameter cartridge end caps are bonded directly to?the media with high strength epoxy or urethane
– 4” diameter cartridge have molded polyester resin or injection molded end caps

*EI (Energy Institute) is the new specification authority. API (American Petroleum Institute) is no longer involved in aviation fuel filtration specifications.

PART NUMBER: I-644C5TB
APPLICATION: Aviation
OUTSIDE DIAMETER (INCH): 6
LENGTH (INCH): 44
FILTER CONSTRUCTION: Fiberglass
END CAP CONFIGURATION: Threaded Base
MICRON RATING (ΜM): 0.4
SEAL MATERIAL: Buna-N
INSIDE DIAMETER (INCH): 3.5
CERTIFICATES: Category C, EI1581
OUTER WRAP: N/A

I-656C5TB Velcon Coalescer Cartridges
I-656C5TB Velcon Coalescer Cartridges Image

Available Stock
Coalescer Cartridges for Aviation & Industrial

Coalescer cartridges are employed as the first stage in filter/separator vessels for hydrocarbon fluids. They perform two functions: (1) coalesce (combine) highly dispersed, emulsified water particles into larger water drops and (2) filter-out particulate contaminants.

Product Features:

– Cost effective particle and emulsified water removal from hydrocarbon fluids
– Easy installation and replacement with one-piece design
– Choice of Threaded Base or Open End cartridges
– Choice of All-Fiberglass Media or Combination Fiberglass and Pleated Media
– Field proven performance
– Ongoing qualification testing to meet changing commercial and military requirements
– Used as a first-stage cartridge in Filter/Separatos
– Remove particulates and coalesce water into large water drops
– Also available in screw base design

Application

Coalescer cartridges are used primarily to coalesce emulsified water and remove particles from hydrocarbon fluids. The largest single application is the filtration of aviation jet fuel. They are also used with other types of fuels, process streams in refineries and petrochemical plants, and condensate streams where natural gas is produced.

Other liquids can be separated if they are immiscible, the specific gravities differ, and high concentrations of surface active agents are not present. As a rule of thumb, if a sample of the mixture readily separates in an hour or two, a coalescer can probably be used. If the mixture hasn’t separated after 24 hours, coalescing probably won’t work.

Construction

Velcon single-unit coalescer elements are offered with Threaded Base or Open Ends and with Fiberglass Media or Fiberglass and Pleated Media combinations.

Threaded Base Coalescers are recommended for use in most applications. They simplify installation and replacement by eliminating the need for cover plates, center plates, nuts, washers, and gaskets. They are for use in Velcon and other make filter/ separators. Threaded base adapters are available to convert vessels presently using open end elements.

Open End Coalescers are offered with single unit construction which reduces the number of gasket seals and improves overall reliability.

All-fiberglass Media Coalescers combine depth particulate filtration with a deep coalescing structure. All-fiberglass designs have successively finer media layers to achieve depth-type filtration of particles.

Combination Fiberglass and Pleated Media Coalescers remove particles primarily in the high surface area pleated core. They have one or more layers of pleated media inside a cylinder of molded fiberglass laminations to provide an extended surface area for particulate filtration. Pleat corrugation and separation materials are used to keep pleats open for full utilization.

Coalescing and filtration performance depends largely on the fiber diameter and bulk density of the fiberglass media. Both the All-Fiberglass and the Combination coalescer cartridge designs incorporate phenolic resin impregnated fiberglass media. Several grades with fiber diameters ranging from 1 to 10 micrometers are used in various combinations to achieve desired results. Velcon’s latest coalescer designs (85, 87 and C5 series cartridges) achieve even higher filtration and coalescing efficiency by incorporating pure micro-glass fibers with diameters of less than 1 micrometer in the pleated media

Description

Model Number System. Refer to the box at right. The one or two digit Series Designator relates to the approx­imate micron rating of each model coalescer cartridge. Note that this is a nominal rating and should be used for?reference only.

The “0”, “2”, and “4” Series all-fiberglass cartridges are rated at 25, 5, and 3 microns respectively. The “2” and “4” Series are commonly used with diesel and other fuel oils, and are a compromise between filtration efficiency (cart­ridge life) and water removing capability. They coalesce gross water, but normally do not remove fine water haze.

The all-fiberglass “6” Series was originally developed for jet fuel service (the original MIL-F-8901 specification). With a 2-micron rating, it has proven to be the most cost effective design in some jet fuel applications. “6” Series cartridges are also used in gasoline filtration service. However, it should be noted that the powerful detergent additives in most automotive gasolines reduce the coalescing capability of this and other cartridge designs.
“83” Series Cartridges. The 1-micron rated “83” Series is?a pleated media/fiberglass cartridge. The very practical “83” Series cartridges have become the most widely used design in applications including gasoline, condensate, and insulating oil filtration.

“85” and “87” Series Cartridges. The “85” Series is rated at 0.5-micron while the “87” Series is rated at 0.3 micron. Both incorporate multi-layered pleated media. The “85” Series has consistently shown superior dirt holding capacity in the field.

JF5 Series Coalescers. JF5 Series Cartridges are Velcon’s newest design. Combined with V5N5 Series Separators, they offer higher flow rates and extended service life. See data sheet #1923 for more info.

EI* 1581 Fifth Edition Cartridges. I-6xxC5 (TB), I-6xxMM, and I-6xxA4 Series of coalescers incorporate a multi-layered pleated media designed to provide superior dirt holding capacity in the field, combined with 0.4 micron efficiency. The I-6xxC5 (TB) replaces both the I-6xx85 (TB) and I-6xx87 (TB) cartridges. These cartridges are available in either threaded base or open-end configuration. See data sheets 1923 and 1934 for more specific information on EI 1581 Fifth Edition.

Cartridge Dimensions. 6” diameter cartridges are the current industry standard. They are offered in lengths of?11”, 14”, 22”, 28”, 33”, 38”, 44”, and 56”. However, not?all series are available in all lengths or in both end cap designs. Contact your Velcon Distributor for details.

4” diameter cartridges are also offered for use with older equipment. They are available in a variety of lengths ranging from 8 to 40 inches.

General Specifications

– 75 psi maximum pressure differential rating
– 5 to 9 pH range
– 150°–160°F max. operating temperature
– Aluminum center tube
– Buna-N gaskets
– Injection molded end caps are standard on 6” diameter threaded base coalescers;
– Aluminum end caps are standard on 6” diameter open end cartridges
– All 6” diameter cartridge end caps are bonded directly to?the media with high strength epoxy or urethane
– 4” diameter cartridge have molded polyester resin or injection molded end caps

*EI (Energy Institute) is the new specification authority. API (American Petroleum Institute) is no longer involved in aviation fuel filtration specifications.

PART NUMBER: I-656C5TB
APPLICATION: Aviation
OUTSIDE DIAMETER (INCH): 6
LENGTH (INCH): 56
FILTER CONSTRUCTION: Fiberglass
END CAP CONFIGURATION: Threaded Base
MICRON RATING (ΜM): 0.4
SEAL MATERIAL: Buna-N
INSIDE DIAMETER (INCH): 3.5
CERTIFICATES: Category C, EI1581
OUTER WRAP: N/A

SO-636V5 Velcon Separator Cartridges
SO-636V5 Velcon Separator Cartridges Image

Available Stock

Features

– Optimum 2nd stage water removal
– Choice of Teflon® Coated Screen, Synthetic or Pleated Paper Media
– Field proven performance
– Largest selection of replacement elements

General

Separator Cartridges are employed as the second stage in filter/separator vessels. Their sole function is to repel coalesced water drops produced by the first stage cartridges while allowing hydrocarbon fluids to pass through. Water drops settle into the filter/separator sump and are not carried downstream. All particle filtering is done by the first stage coalescer cartridge.

PART NUMBER: SO-636V5
APPLICATION: Aviation and Industrial
OUTSIDE DIAMETER (INCH): 6
LENGTH (INCH): 36
INSIDE DIAMETER (INCH): 4.5
END CAP CONFIGURATION: Blind
MEDIA: TCS
TUBE TYPE: Variable
CERTIFICATES: EI1581
SEAL MATERIAL: Buna-N

CDF-230P Fuel Monitor Cartridges Image
CDF-230P Fuel Monitor Cartridges
Available Stock Parker Velcon CDF Fuel Monitor Cartridge, qualified to E... Read More
DFO-644PLF2TB Velcon Filter Cartridges Image
DFO-644PLF2TB Velcon Filter Cartridges
Available Stock Diesel fuel is stored and transferred multiple times from refining to dispensing. Preventative action does not always eliminate contamination. Common contaminants introduced during transportation include both extrem... Read More
DFO-656PLF2TB Velcon Filter Cartridges Image
DFO-656PLF2TB Velcon Filter Cartridges
Available Stock Diesel fuel is stored and transferred multiple times from refining to dispensing. Preventative action does not always eliminate contamination. Common contaminants introduced during transportation include both extre... Read More
I-644MMTB Velcon Coalescer Cartridges Image
I-644MMTB Velcon Coalescer Cartridges
Available Stock I-644MMTB Velcon Coalescer Cartridges for Aviation & Industrial Coalescer cartridges are employed as the first stage in filter/separator vessels for hydrocarbon fluids. They perform two functions: (1) co... Read More
SO-636V5 Velcon Separator Cartridges Image
SO-636V5 Velcon Separator Cartridges
Available Stock Features – Optimum 2nd stage water removal – Choice of Teflon® Coated Screen, Synthetic or Pleated Paper Media – Field proven performance – Largest selection of rep... Read More
ACO-63301P Fuel Monitor Cartriges Image
ACO-63301P Fuel Monitor Cartriges
Available Stock Aquacon® ACO EI 1583 6th Edition Aviation Fuel  Monitor Remove Water and Dirt from Jet Fuel and Avgas Outside-to-In Flow Cartridges Features – Free and emulsified water removal to... Read More
I-644C5TB Coalescer Cartridges Image
I-644C5TB Coalescer Cartridges
Available Stock Coalescer Cartridges for Aviation & Industrial Coalescer cartridges are employed as the first stage in filter/separator vessels for hydrocarbon fluids. They perform two functions: (1) coalesce (combine) ... Read More
I-656C5TB Velcon Coalescer Cartridges Image
I-656C5TB Velcon Coalescer Cartridges
Available Stock Coalescer Cartridges for Aviation & Industrial Coalescer cartridges are employed as the first stage in filter/separator vessels for hydrocarbon fluids. They perform two functions: (1) coalesce (combine) ... Read More
SO-636V5 Velcon Separator Cartridges Image
SO-636V5 Velcon Separator Cartridges
Available Stock Features – Optimum 2nd stage water removal – Choice of Teflon® Coated Screen, Synthetic or Pleated Paper Media – Field proven performance – Largest selection of rep... Read More